FCIA Fire & Smoke Protection Features Barrier Educational and Firestop DIIM (Design, Install, Inspect, Maintain) Educational Symposium

The Oryx Rotana, Doha, Qatar

Join FCIA for this important Symposium on Fire Walls, Fire Barriers, Fire Partitions, Smoke Barriers and Smoke Partitions, Effective Compartmentation and Firestopping to be held at The Oryx Rotana, Doha, Qatar. Hear from industry experts about key fire resistance rated construction and maintenance programs that keep people safe in all types of buildings.

Conference Program Booklet

Speakers & Presentations

Design - Barriers - Where are they located, what are they for?

Mr. Bill McHugh, FCIA

The International Building Code's Chapter 7, Fire and Smoke Protection Features, covers Barrier Construction and the definitions that are associated with the barrier, as does NFPA 101 in Chapter 8.  This session covers fire barriers, smoke barriers, fire walls, fire partitions, smoke partitions as covered in the IBC's Chapter 7 Barriers.  Learn about terminology, what is a barrier, where is it used, fire-ratings and more.

Design & Testing

Mr. Ahmed Eldidi, UL

Mr. Mark Tyrol and Mr. Vidur Berry, FM Approvals

Mr. Randy Clark, Rectorseal

Mr. Ali Kattah, 3M Fire Protection Products

The International Building Code and NFPA 101 mandate the use of tested and listed products that become systems when installed to systems resulting from ASTM & UL Fire-Resistance standards testing.  Fire-resistance-rated walls, floors, fire dampers, fire-rated doors, fire-rated glazing and firestopping are all tested to the standards using common evaluation elements.  Learn in this segment what the submittal and installation looks like for the walls, floors and opening protectives.

Inspection

Mr. Bill McHugh, FCIA

Mr. Sajid Raza, Butler Engineering

Chapter 17 of the International Building Code mandates Special Inspection of several building elements.  In firestopping, ASTM E 2174 & ASTM E 2393 Inspection Standards are used for special inspection.  IAS AC 291 Accredited Special Inspection Agencies bring credibility to the special inspection agency and inspectors.  See pictures of what to look for in the field to find improper firestop installations.

Install

Mr. Bill McHugh, FCIA

Mr. Fouad Hajj, Specified Technologies, Inc.

FM 4991, Standard for the Approval of Firestop Contractors, UL Qualified Firestop Contractor Programs bring quantified qualification of firestop contractor companies and FCIA's Firestop Education Program provides worker education.  Learn about certificateions that are available for installation companies during this session, and see pictures of successful and unsuccessful installations.

Maintenance & Management

Mr. Bill McHugh, FCIA

NFPA 101 and International Fire Code require that fire-resistance properties be maintained throughout the building life-cycle.  Learn about protecting people in existing buildings at this session for Firestopping, Doors and Dampers.

Print
638 Rate this article:
No rating

View More Articles

BUILD YOUR BRAND.
EXPAND YOUR REACH.
ADVERTISE WITH FCIA.

Why Use A Specialty Firestop Contractor?

Cables, pipes of all types, expansion, and building perimeter joints all make breaches in fire-resistance-rated and smoke-resistant assemblies. When breaches that allow penetrations to pass through and joints that allow for movement are required, FCIA Specialty Firestop Installation Contractor Members are the “go to” companies to look for. FCIA Specialty Firestop Installation Contractor Member companies specialize in this highly technical service that protects people, property, and continuity of building operations. They understand how to analyze conditions, correctly select listed firestop SYSTEMS, then install the firestop systems with the utmost attention to detail.

Learn More About FCIA

Why Use A Special Inspection Agency?

FCIA Firestop Special Inspection Agency Members strive to be the best at inspecting highly technical firestop systems. These FCIA Member Inspection Agencies assess the installation of the Specialty Firestop Installation Contractor against the tested and listed system listing that was used to build the firestop system.  Competent, third-party independent inspection by FCIA Firestop Special Inspection Agency Members with the proper equipment, competent personnel, and practical industry experience adds an integral quality check on the firestop installation process. Insist on FCIA Firestop Special Inspection Agencies that know when the installation is right or wrong.

Find a Special Inspection Agency

JOIN AN ELITE GROUP OF FIRESTOP PROFESSIONALS

FCIA members span the globe provided services and materials that uphold the highest level of standards.

0
Firestop Contractors
0
Inspection Agencies
0
Manufacturers
Distributors/Reps

Need Passive Fire Protection Services?

Building Owners and Managers are required by the International Fire Code, NFPA 101, NFPA 1, the National Fire Code of Canada, UAE Fire and Life Safety Code, and other codes to maintain all types of fire-resistance rated and smoke resistant assemblies for the life of the building.